Skip to content
Hannibal Power & Technology
Enquire
HR-1P-110V-15…500A

110V DC Single-Phase Industrial Battery Charger (10A–500A)

Overview

The Hannibal HR-1P-110V is a single-phase 110VDC industrial battery charger and rectifier rated from 10A to 500A, designed to supply the auxiliary loads, switchgear and protection relays of electrical substations. It maintains a stable 110V DC bus for SCADA, control, tripping and signalling circuits, while a standby battery guarantees power backup for substations even during a complete loss of the AC mains.

Engineered for the harshest substation conditions, the unit combines a galvanic isolation transformer with a thyristor-controlled (B6C / 6-pulse) bridge and DSP control to achieve voltage regulation below 1%, low output ripple and a high power factor of 0.9 to 0.99 with the appropriate front end. Float, equalize and boost charge modes keep the battery healthy, while earth leakage monitoring (OPS-02) and DC earth fault detection safeguard the distribution network. Dual battery charger and DC load sharing arrangements are available for utility-grade redundancy.

Key features

  • 110VDC single-phase output, 10A to 500A, for substation and switchgear DC systems.
  • Powers protection relays, SCADA, control and tripping circuits with constant-current operation under load.
  • Thyristor-controlled (B6C / 6-pulse) rectifier with DSP control and voltage regulation < 1%.
  • Galvanic isolation transformer, output ripple < 1% and high power factor (0.9–0.99).
  • Earth leakage monitoring (OPS-02) and DC earth fault detection for network safety.
  • Float, equalize and boost charge modes with current limiting and short-circuit protection.
  • Dual battery charger and DC load sharing options for redundant DC supply.
  • Front-panel interface with measured-values display, alarm logging (event history) and Modbus RS232 / RS485 communication.

Technical specifications

Technical specifications for HR-1P-110V-15…500A
Input voltage (AC)1 x 230V (220 / 240V)
Nominal DC output110 VDC
DC voltage range88–160 VDC
Output current10A to 500A
Rectifier topologyThyristor-controlled, B6C / 6-pulse
Charge modesFloat, Equalize, Boost (auto & manual)
Voltage regulation< 1%
Output ripple< 1% RMS
Power factor0.9 – 0.99 (with PFC front end)
CommunicationRS232 / RS485, Modbus RTU, dry contacts
MonitoringEarth leakage monitoring (OPS-02), DC earth fault detection

Applications

  • Electrical substations and switchgear.
  • Power transmission and distribution.
  • SCADA and protection & control systems.
  • Utility and grid-tie auxiliary DC supplies.
  • Backup and uninterrupted DC supply for critical substation loads.
WhatsApp