HR Series · Three-phase
110V DC Three-Phase Battery Charger for Substation & Switchgear (10A–2500A)
HR-3P-110V-10…2500A
The Hannibal HR-3P-110V is a three-phase 110VDC battery charger and rectifier rated from 10A to 2500A, engineered to provide high-reliability power supply and battery charging for substations and switchgear.

- Nominal DC output
- 110 VDC
- Input voltage (AC)
- 3 x 400V (380 / 415V)
- Charge modes
- Float, Equalize, Boost (auto & manual)
- DC voltage range
- 88–160 VDC
- Redundancy
- Dual DC UPS / dual charger, DC load sharing
- Communication
- RS232 / RS485, Modbus RTU, Modbus/TCP-IP
Overview
The Hannibal HR-3P-110V is a three-phase 110VDC battery charger and rectifier rated from 10A to 2500A, engineered to provide high-reliability power supply and battery charging for substations and switchgear. It feeds the protection relays, SCADA, control and tripping circuits of electrical substations and, combined with a stand-by battery, guarantees power backup for substations, SCADA and switchgear even during a total AC outage.
Three-phase input and 6-pulse (B6C) or 12-pulse (B12C) thyristor-controlled topologies with DSP control deliver high power with low THDi, while a galvanic isolation transformer holds voltage regulation and output ripple below 1%. Earth leakage monitoring (OPS-02), DC earth fault detection and transducers with 0–10V / 4–20mA outputs (OPS-11) provide complete supervision, and dual DC UPS / dual battery charger arrangements with DC load sharing deliver the redundancy that transmission and distribution networks demand.
Key features
- 01Three-phase 110VDC output, 10A to 2500A, for substation and switchgear DC systems.
- 02Supplies protection relays, SCADA, control and tripping circuits with constant-current operation under load.
- 036-pulse (B6C) and 12-pulse (B12C) thyristor-controlled topologies with DSP control and low THDi.
- 04Galvanic isolation transformer, voltage regulation < 1% and output ripple < 1%.
- 05Earth leakage monitoring (OPS-02) and DC earth fault detection for network protection.
- 06Transducers 0–10V / 4–20mA (OPS-11) and dry contact alarm relays for full supervision.
- 07Dual DC UPS / dual battery charger with DC load sharing for utility-grade redundancy.
- 08RS232 / RS485 Modbus RTU and Modbus / TCP-IP communication.
Technical specification
| Input voltage (AC) | 3 x 400V (380 / 415V) |
|---|
| Nominal DC output | 110 VDC |
|---|---|
| DC voltage range | 88–160 VDC |
| Output current | 10A to 2500A |
| Voltage regulation | < 1% |
| Output ripple | < 1% RMS |
| Charge modes | Float, Equalize, Boost (auto & manual) |
|---|
| Monitoring | Earth leakage (OPS-02), DC earth fault, transducers (OPS-11) |
|---|---|
| Communication | RS232 / RS485, Modbus RTU, Modbus/TCP-IP |
| Rectifier topology | Thyristor-controlled, B6C / B12C (6 & 12-pulse) |
|---|---|
| Redundancy | Dual DC UPS / dual charger, DC load sharing |
Applications
- High-voltage and distribution substations.
- Switchgear and protection & control systems.
- Power transmission and distribution networks.
- SCADA and grid-automation systems.
- Power generation and water treatment plants.
Options, standards & platform
Battery compatibility
HR Series chargers are fully compatible with sealed and vented batteries across all major chemistries, with intelligent battery management and temperature compensation to extend service life:
- Maintenance-free and vented: OPzS, OPzV, VRLA (valve-regulated), Gel and AGM lead-acid.
- Nickel-Cadmium (Ni-Cd) — vented and recombination types.
- Lithium-Ion (Li-Ion), Calcium-Ion and Sodium-Ion advanced chemistries.
- Battery monitoring system (Hannibal BMS), DC earth fault detection and battery room temperature sensor options.
- Compatible with leading battery brands including EnerSys and Exide.
Options & accessories
- Alarm & communication interface
- Earth leakage monitoring
- Gauges for analog measurements.
- Output breaker / load dropper module
- Battery temperature compensation
- Input power measurement.
- Transducers (0–10V, 4–20mA)
- Active parallel current sharing
- Fast-acting semiconductor fuses
- Fan failure monitoring.
- 12-pulse operation option, IGBT rectifier, harmonic filter, DC shock / DC filter and one-to-four-step dropper diode voltage regulation.
- Outdoor equipment and ingress protection: IP42, IP54, IP55 and IP65, with altitude operation up to 2000m and natural cooling on request.
- H2S gas compensation for geothermal power plants and the petrochemical industry; anti-seismic design for high-vibration sites.
Standards & compliance
- IEC 60146-1-1 / IEC/NF EN 60146-1-1 — Semiconductor converters (basic requirements).
- IEC 61204-1, IEC 62040-2 (EMC), IEC 60335 — power supply and safety standards.
- ISO 9001, ISO 14001, ISO 27001 management system certifications.
- CE marked, compliant with EMC and Low Voltage directives.
- Total harmonic distortion (THDi) controlled via 6-pulse, 12-pulse and IGBT topologies; harmonic filter available.