220–240V DC Three-Phase Industrial Rectifier & Battery Charger (10A–2500A)

HR-3P-220V-10…2500A

The Hannibal HR-3P-220V is a three-phase 220–240VDC industrial rectifier and battery charger rated from 10A to 2500A for the most demanding sectors — oil & gas, petrochemical, marine, mining and metallurgy.

Industrial Rectifier
Nominal DC output
220–240 VDC
Input voltage (AC)
3 x 400V (380 / 415V), +15% / -10%
Charge modes
Float, Equalize, Boost (auto & manual)
DC voltage range
176–300 VDC
Ambient / altitude
Up to 55°C / up to 2000m
Output current
10A to 2500A

Overview

The Hannibal HR-3P-220V is a three-phase 220–240VDC industrial rectifier and battery charger rated from 10A to 2500A for the most demanding sectors — oil & gas, petrochemical, marine, mining and metallurgy. It supplies a powerful, stable high-voltage DC bus and keeps the standby battery charged, protecting emergency, control and shutdown systems in the harshest operating conditions.

Available in 6-pulse (B6C) and 12-pulse (B12C) thyristor-controlled topologies with DSP control, the HR-3P-220V combines a galvanic isolation transformer with ripple suppression to hold voltage regulation and output ripple below 1% while keeping input THDi low. It is rated for continuous full-load operation at high ambient temperature up to 55°C, altitude operation up to 2000m, an input voltage tolerance of +15% / -10% and frequency tolerance of ±10%. Anti-seismic design, fast-acting semiconductor fuses (OPS-14) and outdoor IP55 / IP65 enclosures make it a rugged, long-life solution for exposed and corrosive sites.

Key features

  • Three-phase 220–240VDC output, 10A to 2500A, for heavy industrial and process DC systems.
  • 6-pulse (B6C) and 12-pulse (B12C) thyristor-controlled topologies with DSP control and low THDi.
  • Galvanic isolation transformer, voltage regulation < 1% and output ripple < 1%.
  • Continuous full-load operation at high ambient temperature up to 55°C and altitude up to 2000m.
  • Wide input tolerance: voltage +15% / -10%, frequency ±10%, 50 or 60 Hz.
  • Anti-seismic design and fast-acting semiconductor fuses (OPS-14) for fault safety.
  • H2S gas compensation option and outdoor IP55 / IP65 enclosures for corrosive sites.
  • Float, equalize and boost charge modes with RS232 / RS485 Modbus RTU communication.

Technical specification

Input specifications for HR-3P-220V-10…2500A
Input voltage (AC)3 x 400V (380 / 415V), +15% / -10%

Applications

  • Oil & gas, petrochemical and refineries.
  • Marine and offshore platforms.
  • Chemical, mining and metallurgy plants.
  • Power generation and water treatment.
  • Outdoor and seismic-prone harsh environments.

Options, standards & platform

Battery compatibility

HR Series chargers are fully compatible with sealed and vented batteries across all major chemistries, with intelligent battery management and temperature compensation to extend service life:

  1. Maintenance-free and vented: OPzS, OPzV, VRLA (valve-regulated), Gel and AGM lead-acid.
  2. Nickel-Cadmium (Ni-Cd) — vented and recombination types.
  3. Lithium-Ion (Li-Ion), Calcium-Ion and Sodium-Ion advanced chemistries.
  4. Battery monitoring system (Hannibal BMS), DC earth fault detection and battery room temperature sensor options.
  5. Compatible with leading battery brands including EnerSys and Exide.
Options & accessories
  1. Alarm & communication interface
  2. Earth leakage monitoring
  3. Gauges for analog measurements.
  4. Output breaker / load dropper module
  5. Battery temperature compensation
  6. Input power measurement.
  7. Transducers (0–10V, 4–20mA)
  8. Active parallel current sharing
  9. Fast-acting semiconductor fuses
  10. Fan failure monitoring.
  11. 12-pulse operation option, IGBT rectifier, harmonic filter, DC shock / DC filter and one-to-four-step dropper diode voltage regulation.
  12. Outdoor equipment and ingress protection: IP42, IP54, IP55 and IP65, with altitude operation up to 2000m and natural cooling on request.
  13. H2S gas compensation for geothermal power plants and the petrochemical industry; anti-seismic design for high-vibration sites.
Standards & compliance
  1. IEC 60146-1-1 / IEC/NF EN 60146-1-1 — Semiconductor converters (basic requirements).
  2. IEC 61204-1, IEC 62040-2 (EMC), IEC 60335 — power supply and safety standards.
  3. ISO 9001, ISO 14001, ISO 27001 management system certifications.
  4. CE marked, compliant with EMC and Low Voltage directives.
  5. Total harmonic distortion (THDi) controlled via 6-pulse, 12-pulse and IGBT topologies; harmonic filter available.