HR Series · Single-phase
125V DC Single-Phase Industrial Battery Charger (10A–500A)
HR-1P-125V-15…500A
The Hannibal HR-1P-125V is a single-phase 125VDC industrial battery charger that delivers a regulated 10A to 500A DC supply to switchgear, utility control rooms and protection systems.

- Nominal DC output
- 125 VDC
- Input voltage (AC)
- 1 x 230V (220 / 240V)
- Charge modes
- Float, Equalize, Boost (auto & manual)
- Rectifier topology
- Thyristor-controlled, B6C / 6-pulse
- DC voltage range
- 88–160 VDC
- Communication
- RS232 / RS485, Modbus RTU, dry contacts
Overview
The Hannibal HR-1P-125V is a single-phase 125VDC industrial battery charger that delivers a regulated 10A to 500A DC supply to switchgear, utility control rooms and protection systems. Combined with a stand-by battery, it forms a reliable DC power supply and battery charger that protects critical 125V loads from voltage dips, brown-outs and complete mains failure.
The charger pairs a galvanic isolation transformer with a thyristor-controlled (B6C / 6-pulse) bridge and DSP control to hold voltage regulation under 1% and output ripple under 1%, even under fluctuating load. An intuitive LCD display with keypad and menu navigation provides a clear front-panel interface for measured-values display, programmable operation parameters, calibration functions and a time-stamped alarm & event logger. Built-in intelligent battery management with float, equalize and boost modes supports lead-acid, Ni-Cd, VRLA, OPzS and OPzV batteries, with each unit carrying a clear equipment label, model info and serial number for traceable service and support.
Key features
- 01125VDC single-phase output, 10A to 500A, for switchgear and utility DC systems.
- 02Thyristor-controlled (B6C / 6-pulse) bridge with DSP control, voltage regulation < 1% and ripple < 1%.
- 03Galvanic isolation transformer with ripple suppression for clean DC distribution.
- 04Built-in intelligent battery management with float, equalize and boost charge modes.
- 05LCD display with keypad and menu navigation, measured-values display and analog gauges / indicators (OPS-04).
- 06Programmable operation parameters and calibration functions for voltage and current.
- 07Alarm & event logger with date and time-stamped logs for preventive maintenance.
- 08RS232 / RS485 Modbus RTU communication, dry contact alarm relays and automatic restart after fault.
Technical specification
| Input voltage (AC) | 1 x 230V (220 / 240V) |
|---|
| Nominal DC output | 125 VDC |
|---|---|
| DC voltage range | 88–160 VDC |
| Output current | 10A to 500A |
| Voltage regulation | < 1% |
| Output ripple | < 1% RMS |
| Charge modes | Float, Equalize, Boost (auto & manual) |
|---|
| Display | LCD with keypad & menu navigation, analog gauges (OPS-04) |
|---|---|
| Communication | RS232 / RS485, Modbus RTU, dry contacts |
| Logging | Date & time-stamped alarm & event logger |
| Rectifier topology | Thyristor-controlled, B6C / 6-pulse |
|---|
Applications
- Switchgear and protection relay DC supplies.
- Utility substations and control rooms.
- Power generation auxiliary systems.
- Industrial process control.
- Backup DC supply for critical 125V loads.
Options, standards & platform
Battery compatibility
HR Series chargers are fully compatible with sealed and vented batteries across all major chemistries, with intelligent battery management and temperature compensation to extend service life:
- Maintenance-free and vented: OPzS, OPzV, VRLA (valve-regulated), Gel and AGM lead-acid.
- Nickel-Cadmium (Ni-Cd) — vented and recombination types.
- Lithium-Ion (Li-Ion), Calcium-Ion and Sodium-Ion advanced chemistries.
- Battery monitoring system (Hannibal BMS), DC earth fault detection and battery room temperature sensor options.
- Compatible with leading battery brands including EnerSys and Exide.
Options & accessories
- Alarm & communication interface
- Earth leakage monitoring
- Gauges for analog measurements.
- Output breaker / load dropper module
- Battery temperature compensation
- Input power measurement.
- Transducers (0–10V, 4–20mA)
- Active parallel current sharing
- Fast-acting semiconductor fuses
- Fan failure monitoring.
- 12-pulse operation option, IGBT rectifier, harmonic filter, DC shock / DC filter and one-to-four-step dropper diode voltage regulation.
- Outdoor equipment and ingress protection: IP42, IP54, IP55 and IP65, with altitude operation up to 2000m and natural cooling on request.
- H2S gas compensation for geothermal power plants and the petrochemical industry; anti-seismic design for high-vibration sites.
Standards & compliance
- IEC 60146-1-1 / IEC/NF EN 60146-1-1 — Semiconductor converters (basic requirements).
- IEC 61204-1, IEC 62040-2 (EMC), IEC 60335 — power supply and safety standards.
- ISO 9001, ISO 14001, ISO 27001 management system certifications.
- CE marked, compliant with EMC and Low Voltage directives.
- Total harmonic distortion (THDi) controlled via 6-pulse, 12-pulse and IGBT topologies; harmonic filter available.