Skip to content
Hannibal Power & Technology
Enquire

HR Series · Single-phase

48V Single-Phase Rectifier & Battery Charger for Telecom & Backup Power (10A–500A)

HR-1P-48V-15…500A

The Hannibal HR-1P-48V is a single-phase 48VDC rectifier and battery charger purpose-built for telecom, data centers and server rooms where a continuous, uninterrupted DC supply is non-negotiable.

Industrial Rectifier
Nominal DC output
48 VDC
Input voltage (AC)
1 x 230V (220 / 240V)
Charge modes
Float, Equalize, Boost (auto & manual)
Rectifier topology
Thyristor-controlled, B6C / 6-pulse
Communication
RS232 / RS485, Modbus RTU, optional CANBUS
DC voltage range
36–75 VDC

Overview

The Hannibal HR-1P-48V is a single-phase 48VDC rectifier and battery charger purpose-built for telecom, data centers and server rooms where a continuous, uninterrupted DC supply is non-negotiable. Available from 10A to 500A, it acts as a compact DC UPS — rectifying single-phase AC to a stable 48V DC bus while keeping the standby battery fully charged, so connected loads ride through power interruptions without a break.

A galvanic isolation transformer and thyristor-controlled (B6C / 6-pulse) front end deliver low output ripple, effective ripple suppression and voltage regulation better than 1%, protecting sensitive communication hardware. Float, equalize and boost charge modes with battery temperature compensation extend battery life across VRLA, AGM, Gel, lead-acid and Ni-Cd chemistries from leading brands such as EnerSys and Exide. With RS232 / RS485 Modbus communication, optional CANBUS for current sharing and active parallel current sharing, the HR-1P-48V scales cleanly as telecom and backup-power demands grow.

Key features

  • 48VDC single-phase output, 10A to 500A, optimised for telecom and backup-power DC distribution.
  • Operates as a DC UPS / AC-DC converter with seamless operation while mains fail.
  • Thyristor-controlled (B6C / 6-pulse) bridge with DSP control, voltage regulation < 1% and output ripple < 1%.
  • Galvanic isolation transformer for ripple suppression and full input/output isolation.
  • Float, equalize and boost charge modes with battery temperature compensation (OPS-06).
  • Active parallel current sharing (OPS-13) and optional CANBUS for current sharing in redundant systems.
  • RS232 / RS485 Modbus RTU, dry contact alarm relays and alarm & communication interface (OPS-01).
  • Soft start, current limiting, short-circuit and over-temperature protection for reliable continuous duty.

Technical specification

Input specifications for HR-1P-48V-15…500A
Input voltage (AC)1 x 230V (220 / 240V)
Power factor0.75 / 0.80 nominal (1P)

Applications

  • Telecommunication networks and base stations.
  • Data centers and server rooms (48V DC backup).
  • Broadcast and network equipment.
  • Renewable and hybrid power auxiliary systems.
  • General industrial 48V DC backup and uninterrupted supply.

Options, standards & platform

Battery compatibility

HR Series chargers are fully compatible with sealed and vented batteries across all major chemistries, with intelligent battery management and temperature compensation to extend service life:

  1. Maintenance-free and vented: OPzS, OPzV, VRLA (valve-regulated), Gel and AGM lead-acid.
  2. Nickel-Cadmium (Ni-Cd) — vented and recombination types.
  3. Lithium-Ion (Li-Ion), Calcium-Ion and Sodium-Ion advanced chemistries.
  4. Battery monitoring system (Hannibal BMS), DC earth fault detection and battery room temperature sensor options.
  5. Compatible with leading battery brands including EnerSys and Exide.
Options & accessories
  1. Alarm & communication interface
  2. Earth leakage monitoring
  3. Gauges for analog measurements.
  4. Output breaker / load dropper module
  5. Battery temperature compensation
  6. Input power measurement.
  7. Transducers (0–10V, 4–20mA)
  8. Active parallel current sharing
  9. Fast-acting semiconductor fuses
  10. Fan failure monitoring.
  11. 12-pulse operation option, IGBT rectifier, harmonic filter, DC shock / DC filter and one-to-four-step dropper diode voltage regulation.
  12. Outdoor equipment and ingress protection: IP42, IP54, IP55 and IP65, with altitude operation up to 2000m and natural cooling on request.
  13. H2S gas compensation for geothermal power plants and the petrochemical industry; anti-seismic design for high-vibration sites.
Standards & compliance
  1. IEC 60146-1-1 / IEC/NF EN 60146-1-1 — Semiconductor converters (basic requirements).
  2. IEC 61204-1, IEC 62040-2 (EMC), IEC 60335 — power supply and safety standards.
  3. ISO 9001, ISO 14001, ISO 27001 management system certifications.
  4. CE marked, compliant with EMC and Low Voltage directives.
  5. Total harmonic distortion (THDi) controlled via 6-pulse, 12-pulse and IGBT topologies; harmonic filter available.
WhatsApp