HR Series · Three-phase
48V Three-Phase Rectifier & Battery Charger for Telecom DC Power (10A–2500A)
HR-3P-48V-10…2500A
The Hannibal HR-3P-48V is a three-phase 48VDC rectifier and battery charger built for high-capacity telecom DC power, large data centers and server rooms requiring from 10A up to 2500A of continuous, uninterrupted DC sup…

- Nominal DC output
- 48 VDC
- Input voltage (AC)
- 3 x 400V (380 / 415V)
- Charge modes
- Float, Equalize, Boost (auto & manual)
- DC voltage range
- 36–75 VDC
- THDi
- < 30% (6-pulse), < 12% (12-pulse), < 5% (IGBT)
- Output current
- 10A to 2500A
Overview
The Hannibal HR-3P-48V is a three-phase 48VDC rectifier and battery charger built for high-capacity telecom DC power, large data centers and server rooms requiring from 10A up to 2500A of continuous, uninterrupted DC supply. The balanced three-phase input enables high output power with high efficiency, making it the backbone of mission-critical 48V DC infrastructure.
Offered in 6-pulse (B6C) and 12-pulse (B12C) thyristor-controlled topologies with DSP control, the HR-3P-48V keeps input total harmonic distortion low and holds voltage regulation and output ripple below 1% through a galvanic isolation transformer and effective ripple suppression. Battery temperature compensation (OPS-06) and intelligent float, equalize and boost charging maximise the life of VRLA, AGM, Gel, OPzV, lead-acid, Ni-Cd and Li-Ion batteries from brands such as EnerSys and Exide. With a power factor of 0.9 to 0.99, active parallel current sharing and CANBUS for current sharing, it functions as a fully featured DC UPS and AC-DC converter.
Key features
- 01Three-phase 48VDC output, 10A to 2500A, for high-power telecom and data-center DC.
- 02Operates as a DC UPS / AC-DC converter with continuous operation while mains fail.
- 036-pulse (B6C) and 12-pulse (B12C) thyristor-controlled topologies with DSP control and low THDi.
- 04Galvanic isolation transformer, voltage regulation < 1% and output ripple < 1%.
- 05Battery temperature compensation (OPS-06) and intelligent float / equalize / boost charging.
- 06Power factor 0.9–0.99 with active parallel current sharing (OPS-13) and CANBUS current sharing.
- 07Wide battery support: VRLA, AGM, Gel, OPzV, OPzS, lead-acid, Ni-Cd and Li-Ion.
- 08RS232 / RS485 Modbus RTU, Modbus / TCP-IP and dry contact alarm relays.
Technical specification
| Input voltage (AC) | 3 x 400V (380 / 415V) |
|---|---|
| THDi | < 30% (6-pulse), < 12% (12-pulse), < 5% (IGBT) |
| Power factor | 0.9 – 0.99 |
| Nominal DC output | 48 VDC |
|---|---|
| DC voltage range | 36–75 VDC |
| Output current | 10A to 2500A |
| Voltage regulation | < 1% |
| Output ripple | < 1% RMS |
| Charge modes | Float, Equalize, Boost (auto & manual) |
|---|
| Communication | RS232 / RS485, Modbus RTU, Modbus/TCP-IP, CANBUS |
|---|
| Rectifier topology | Thyristor-controlled, B6C / B12C (6 & 12-pulse) |
|---|
Applications
- Telecommunication core and transport networks.
- Large data centers and server rooms.
- Renewable and hybrid power systems.
- Broadcast and ICT infrastructure.
- High-power 48V DC backup and distribution.
Options, standards & platform
Battery compatibility
HR Series chargers are fully compatible with sealed and vented batteries across all major chemistries, with intelligent battery management and temperature compensation to extend service life:
- Maintenance-free and vented: OPzS, OPzV, VRLA (valve-regulated), Gel and AGM lead-acid.
- Nickel-Cadmium (Ni-Cd) — vented and recombination types.
- Lithium-Ion (Li-Ion), Calcium-Ion and Sodium-Ion advanced chemistries.
- Battery monitoring system (Hannibal BMS), DC earth fault detection and battery room temperature sensor options.
- Compatible with leading battery brands including EnerSys and Exide.
Options & accessories
- Alarm & communication interface
- Earth leakage monitoring
- Gauges for analog measurements.
- Output breaker / load dropper module
- Battery temperature compensation
- Input power measurement.
- Transducers (0–10V, 4–20mA)
- Active parallel current sharing
- Fast-acting semiconductor fuses
- Fan failure monitoring.
- 12-pulse operation option, IGBT rectifier, harmonic filter, DC shock / DC filter and one-to-four-step dropper diode voltage regulation.
- Outdoor equipment and ingress protection: IP42, IP54, IP55 and IP65, with altitude operation up to 2000m and natural cooling on request.
- H2S gas compensation for geothermal power plants and the petrochemical industry; anti-seismic design for high-vibration sites.
Standards & compliance
- IEC 60146-1-1 / IEC/NF EN 60146-1-1 — Semiconductor converters (basic requirements).
- IEC 61204-1, IEC 62040-2 (EMC), IEC 60335 — power supply and safety standards.
- ISO 9001, ISO 14001, ISO 27001 management system certifications.
- CE marked, compliant with EMC and Low Voltage directives.
- Total harmonic distortion (THDi) controlled via 6-pulse, 12-pulse and IGBT topologies; harmonic filter available.